e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
June 2004 © TOSHIBA TEC
2 - 160
257
Counter
Counter copy
ALL
-
<1-2>
-
1) Electrical counter
!
Backup counter
2) Backup counter
!
Electrical counter
(P. 2-239 "Fig. 2-7")
-
258
Mainte-
nance
FSMS acceptance
ALL
1
<0-2>
SYS
Sets whether the FSMS
connection is accepted
or not.
0: Prohibited
1: Accepted (USB nor-
mal connection)
2: Accepted (USB
forcible connection)
1
259
Network
Storage period trial and pri-
vate
PRT
14
<0-35>
SYS
0: No limits
1 to 30: 1 to 30 days
31: 1hour
32: 2hours
33: 4hours
34: 8hours
35: 12hours
1
260
Network
Web data retention period
SCN
10
<3 digits>
SYS
When a certain period
of time has passed
without operation after
accessing TopAccess,
the data being regis-
tered is automatically
reset. This period is set
at this code.
(Unit: Minute)
1
263
User
interface
Administrator's password
(Maximum 10 digits)
ALL
123456
<10
digits>
-
The password can be
entered in alphabets
and figures (A-Z, a-z, 0-
9) within 10 digits.
11
264
Network
File retention period
SCN
30
<0-999>
SYS
0: No limits
1 to 999: 1 to 999 days
1
265
Network
Maximum data capacity at
E-mailing
SCN
30
<2-30>
SYS
2 to 30 M bytes
1
266
Network
Maximum data capacity at
Internet FAX
ALL
30
<2-30>
SYS
2 to 30 M bytes
1
267
Elec-
tronic Fil-
ing
Full guarantee of docu-
ments in Electronic Filing
when HDD is full
ALL
0
<0-1>
SYS
Sets the file retention
level when editing the
files in the Electronic
Filing (at CutDoc/Save-
Doc command execu-
tion).
0: Not full retained
1: Fully retained -
Retains the source
file until CutDoc/
SaveDoc command
is completed.
*
The file is not
deleted even if the
HDD has become
full during the exe-
cution of command
when “1” is set.
1
Setting mode (08) <e-STUDIO202L/232/282>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
06/01
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......