June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 239
2
<<Procedure to copy the total counter value (08-257)>>
(1)
Turn ON the power while [0] and [8] are pressed simultaneously.
(2)
Key in the code “257” with the digital keys and press the [START] button (the following is dis-
played).
Note:
Note:
Before performing the following operations, note the current counter values.
Fig. 2-7
(3)
Key in the value “1” or “2” with the digital key and press the [START] button.
The value entered is displayed on the left of the “%”, and the [ENTER] button is displayed.
Note:
Note:
The value can be erased by pressing the [CLEAR] button to change as long as the [START] but-
ton is not pressed. (The value on the left of the “%” is reset to “0” by pressing the [CLEAR] but-
ton.)
•
Key in “1” to copy the value of the total
counter (LGC board) (A) onto the value of
the backup counter (SYS board) (B).
Fig. 2-8
(A)
(B)