e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
June 2004 © TOSHIBA TEC
3 - 2
(4)
After about two minutes, the value B automatically starts changing.
Fig.3-3
(5)
After a short time, the value B becomes stable and the display changes as follows.
Fig.3-4
(6)
Check if the value B is within the range of 235 to 245 (the output voltage range of the auto-toner
sensor is 2.35 V to 2.45 V).
(7)
If the value B is not within the range of 235 to 245, press the Up or Down button to adjust the
value manually.
Note:
Note:
The relation between the button and the values A and B is as follows.
(8)
Press the [ENTER] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
Fig.3-5
(9)
Turn the power OFF.
(10) Install the toner cartridge.
Button to be pressed
Value A
Value B
Up
Increased
Increased
Down
Decreased
Decreased
230%
128
200
TEST MODE
WAIT
A3
128
240%
128
200
ADJUSTMENT MODE
A3
150
A
B
[ENTER]
or
[INTERRUPT]
100%
TEST MODE
A3
A
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......