June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 47
5
5.1.6
Drive system related service call
[C010]
Main motor is abnormal
Is the main motor working? (Perform the output check in the test mode: 03-101/151)
l
l
l
l
l
l
l
l
#
NO
1) Check if the connector CN1 of the main motor is disconnected.
2) Check if the connector CN305 on the LGC board is disconnected.
3) Check if the connector pins are disconnected and the harnesses are
open circuited.
4) Check if the conductor patterns on the main motor board and LGC
board are short circuited or open circuited.
5) Replace the main motor.
6) Replace the LGC board.
YES
Is the LED on the main motor board lit without flickering?
l
l
l
l
l
l
#
NO
1) Check if the connector pins are disconnected and the harnesses are
open circuited.
2) Check if the conductor patterns on the main motor board and LGC
board are short circuited or open circuited.
3) Replace the main motor.
4) Replace the LGC board.
YES
1) Check if the PLL lock signal CN305-B8 output from the LGC board is always level “L”?
2) Check if the voltage supplied to the CPU input terminal IC24-12 is always “L”?
3) Replace the LGC board.
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......