June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 65
6
(16) Turn OFF the power of the equipment.
(17) Perform the initialization of the updating data (NVRAM updating).
•
Turn ON the power while [0] button and [8] button are pressed simultaneously.
•
Key in “947”, and then press the [START] button.
•
Press the [INITIALIZE] button.
[B]
Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data was overwritten properly.
<Updating Master data>
08-925: Version of UI data language 2 in HDD
08-926: Version of UI data language 3 in HDD
08-927: Version of UI data language 4 in HDD
08-928: Version of UI data language 5 in HDD
08-929: Version of UI data language 6 in HDD
08-931: Version of UI data language 7 in HDD
08-933: HDD data unit version
08-934: Version of Web UI data language 1 in HDD
08-935: Version of Web UI data language 2 in HDD
08-936: Version of Web UI data language 3 in HDD
08-937: Version of Web UI data language 4 in HDD
08-938: Version of Web UI data language 5 in HDD
08-939: Version of Web UI data language 6 in HDD
<Updating System ROM>
08-900: System ROM version
08-922: UI data fixed section version
08-923: UI data common section version
08-924: Version of UI data language 1 in HDD
08-930: Version of UI data in FROM displayed at power ON
<Updating Engine ROM>
08-903: Engine ROM version
<Updating Scanner ROM>
08-905: Scanner ROM version
<Updating NIC ROM>
08-916: NIC ROM version
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......