e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
June 2004 © TOSHIBA TEC
3 - 18
[F]
Top margin
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
#
(Adjustment Mode)
(2)
Open the platen cover or RADF.
(3)
Press [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and standard drawer of the
equipment (Refer to *).
*Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4)
Measure the blank area E at the leading edge of the copied image.
(5)
Check if the blank area E is within the range of 3 ± 0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
#
(Key in the code [430])
#
[START]
#
(Key in a value (acceptable values: 0 to 255))
#
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
#
(“100% A” is displayed.)
*The larger the adjustment value is, the wider the blank area becomes (approx. 0.04 mm/step).
Fig.3-16
E
Feeding direction
04/09