e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
June 2004 © TOSHIBA TEC
6 - 22
[A]
Update Procedure
Since the procedure differs depending on the data, see the each procedure below.
Important:
•
Turn OFF the power before installing or removing the download jig.
•
Do not turn OFF the power during the update. The data could be damaged and not be oper-
ated properly.
<Updating Engine ROM>
(1)
Install the ROM to the download jig.
Make sure the direction is correct (P.6-3 "Fig.6-3").
(2)
Turn OFF the power of the equipment.
(3)
Take off the connector cover.
Fig.6-20
(4)
Remove the cover plate.
Fig.6-21
Connector cover
Cover plate