June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 101
5
8) Solid copy
Fig. 5-8
Defective area
Step
Check items
Prescription
Exposure lamp and
inverter
1
Does the exposure lamp light?
Check if the connector contacts with
the exposure lamp terminal.
Replace the defective inverter.
Scanner
2
Is there any foreign matter on the
light path?
Remove it.
Bedewed scanner and
drum
3
Is the scanner or drum bedewed?
Clean the mirrors, lens and drum.
Keep the power cord plugged in all
trough the day and night.
(For the model with damp heater)
Main charger
4
Is the main charger securely
installed?
Install it securely.
5
Is the needle electrode broken?
Replace the needle electrode.
High-voltage transformer
(Main charger)
6
Is the high-voltage transformer out-
put defective?
Adjust the output, or replace the
transformer.
7
Are the connectors of the high-volt-
age harness securely connected? Is
the harness open circuited?
Reconnect the harness securely.
Replace the high-voltage harness.
CCD, SLG, SYS, LGC
boards and harnesses
8
Are the connectors securely con-
nected?
Check if the harnesses connecting
the boards are open circuited.
Connect the connectors securely.
Replace the harness.
Feeding direction
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......