e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
June 2004 © TOSHIBA TEC
3 - 12
Remark:
When the adjustment (05-421) is performed, the same adjustment for FAX (05-422) is automati-
cally and consecutively performed.
3.2.4
Scanner related adjustment
[A]
Image distortion
Fig.3-9
When the value is 1.
[0] [5] [Power ON]
#
[1] ([3](05-445, 498) for duplexing)
#
[FAX]
A:
05-401 (Upper drawer, A3/LD)
#
200±0.5 mm (0.125 mm/step)
B:
05-411 (Upper drawer, A3/LD)
#
52±0.5 mm (0.05 mm/step)
#
Key in the same value for 05-410.
C:
05-421 (Upper drawer, A3/LD)
#
200±0.5 mm (0.125 mm/step)
D:
05-440 (Upper drawer, A3/LD), 441 (Lower drawer, A4/LT), 444 (PFP, A4/LT),
443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Duplexing, A3/LD)
#
52±0.5 mm(0.4 mm/step)
E:
05-498-0 (Upper drawer, A3/LD),
498-1 (Upper drawer, A4/LT))
#
52±0.5 mm (0.05 mm/step)
Feeding direction
Feeding direction
Step 1
A
Step 2
C
B
D
05/05