e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 111
2
518
Fuser
Fuser roller temperature
during printing
(Side thermistor/Thick
paper 3)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
520
Fuser
Fuser roller temperature
during printing
(Center thermistor/Enve-
lope)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
521
Fuser
Fuser roller temperature
during printing
(Side thermistor/Envelope)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
523
Fuser
Pre-running time for first
printing
(Envelope)
ALL
10
<0-15>
M
0: Invalid 1: 1 sec.
2: 2 sec.
3: 3 sec.
4: 4 sec.
5: 5 sec.
6: 6 sec.
7: 7 sec.
8: 8 sec.
9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
1
525-0
Fuser
Temperature
drop switching
time setting
during printing
(Center ther-
mistor)
The first
drop
ALL
20
<0-200>
M
This code is valid only
when “20” is set to 08-
535.
Setting value x 5 sec.:
from 0 to 1,000 sec.
later
4
525-1
The sec-
ond drop
ALL
38
<0-200>
M
4
525-2
The third
drop
ALL
75
<0-200>
M
4
525-3
The fourth
drop
ALL
75
<0-200>
M
4
Setting mode (08) <e-STUDIO200L/230/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
05/05
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......