June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
6 - 53
6
(5)
Turn ON the power while [0] button and [8] button are pressed simultaneously. Updating starts
automatically and the LED on the download jig lights.
(6)
After the update is completed properly, the LED on the download jig blinks. The LED starts blink-
ing in approx. 30 sec. since the update starts. It is assumed that the update is failed if it does not
start blinking even though 1 min. has passed. In this case, turn OFF the power and check the fol-
lowing items. Then, clear the problem and restart updating from the beginning.
•
Is the download jig connected properly?
•
Is the ROM installed to the download jig properly?
•
Is the updating data written on the ROM of the download jig properly?
•
Do the download jig and the equipment operate properly?
(7)
Turn OFF the power, remove the download jig and install the cover plate.
(8)
In the FAX Clearing Mode, perform the “FAX Set up”.
•
Confirm the destination setting is correct in the Setting Mode (08).
08-201: Destination setting of the equipment
08-701: Destination setting of the FAX machine
•
Turn ON the power while [1] button and [*] button are pressed simultaneously.
•
Key in “100”.
•
Press the [START] button.
Notes:
If the equipment does not work properly after the operation (8), follow the procedure below and
then perform the “Clearing the image data” in the FAX Clearing Mode to erase the image data in
the memory.
•
Confirm the destination setting is correct in the Setting Mode (08).
08-201: Destination setting of the equipment
08-701: Destination setting of the FAX machine
•
Turn ON the power while [1] button and [*] button are pressed simultaneously.
•
Key in “102”.
•
Press the [START] button.
[B]
Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
was overwritten properly.
<Updating Engine ROM>
08-903: Engine ROM version
<Updating Scanner ROM>
08-905: Scanner ROM version
<Updating RADF ROM>
08-907: RADF ROM version
<Updating Finisher ROM>
08-908: Finisher ROM version
<Updating FAX ROM>
08-915: FAX ROM version
05/11
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......