June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 99
3
3.14 Key Copy Counter (MU-8, MU-10)
To make a key copy counter available, the following 2 components must be installed to the equipment.
Fig.3-133
<Installation procedure>
(1)
Remove the rear cover.
(2)
Remove the right upper cover-3, and cut
open the window for the key copy counter.
Fig.3-134
(3)
Pull out the harness connector from the hole
of the machine frame, and cut the short har-
ness of the connector. (Treat the cut harness
properly to avoid it causing a short circuit
with the machine frame.) Then, disconnect
the dummy connector.
Fig.3-135
Counter socket
MU-10
Key copy counter
MU-8
Right upper cover-3
Dummy connector
Harness connector