June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 183
2
508
Image
Custom Mode setting
PPC
0
<0-3>
SYS
0: Not used
1: Custom Mode 1
when Text/Photo is
set as a base
2: Custom Mode 2
when Text is set as
a base
3: Custom Mode 3
when Photo is set
as a base
1
509
Image
Error diffusion and dither
setting at a photo mode
(Custom Mode)
PPC
1
<0-1>
SYS
Switches the image
processing method
when Custom Mode 3
is set.
0: Error diffusion
1: Dither
1
515
Fuser
Temperature setting of
warming-up
(Center thermistor)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
516
Fuser
Temperature setting of
warming-up
(Side thermistor)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
518
Fuser
Fuser roller temperature
during printing
(Side thermistor/Thick
paper 3)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
520
Fuser
Fuser roller temperature
during printing
(Center thermistor/Enve-
lope)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
Setting mode (08) <e-STUDIO202L/232/282>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
05/11
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......