June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 25
3
3.3.6
Adjustment of smudged/faint text
The smudged/faint text can be set at the following codes.
< Adjustment Mode (05) >
< e-STUDIO 200L/230/280 >
< e-STUDIO 202L/232/282 >
*
The values in "( )" are the adjustment codes of the Custom Mode.
Make a test copy and compare the image obtained with the current settings; if necessary, make
adjustment using the following procedure.
<Procedure>
Procedure is same as that of
!
P.3-21 "3.3.1 Density adjustment".
3.3.7
Gamma balance adjustment < e-STUDIO 202L/232/282 >
The gamma balance is adjusted by adjusting the density at the Black Mode. The adjustment is per-
formed by selecting its density area from the following: low density, medium density and high density.
< Adjustment Mode (05) >
Original mode
Item to be adjusted
Remarks
Text/Photo
653
(928)
Adjustment of smudged/faint
spotted text
When the value increases, the faint text is improved.
When the value decreases, the smudged text is
improved.
Acceptable values: 0 to 255 (Default: 192)
Note:
Note:
Remember the image specifications and life
span of the replacing parts may not meet the
standard when the setting value is changed
from the default value.
Original mode
Item to be adjusted
Remarks
Text/Photo
648
(928)
Adjustment of smudged/faint
spotted text
When the value increases, the faint text is improved.
When the value decreases, the smudged text is
improved.
Acceptable values: 0 to 4 (Default: 2)
Note:
Note:
Remember the image specifications and life
span of the replacing parts may not meet the
standard when the setting value is changed
from the default value.
Language and screen
Item to be adjusted
Remarks
Smooth
(PS)
Detail
(PS)
Smooth
(PCL)
Detail
(PCL)
596-0
597-0
598-0
599-0
Low density
The larger the value is, the
density of the item to be
adjusted becomes darker.
Acceptable values:
0 to 255. (Default: 128)
596-1
597-1
598-1
599-1
Medium density
596-2
597-2
598-2
599-2
High density
05/11
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......