e-STUDIO200L/202L/230/232/280/282 FIRMWARE UPDATING
June 2004 © TOSHIBA TEC
6 - 6
(6)
“Update Completed!!” is displayed at the bottom of the LCD screen after the updating is com-
pleted properly.
Fig.6-7
“Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com-
pleted properly. Turn OFF the power, and then check the following items. After confirming and
clearing the problems, restart updating from the beginning.
•
Is the download jig connected properly?
•
Is the updating data written to the download jig properly?
•
Do the download jig and the equipment operate properly?
Fig.6-8
(7)
Turn OFF the power, and then remove the download jig.
(8)
Perform the “Updating System ROM” continuously.
!
P.6-11 "6.1.2 PWA-DWNLD-350-JIG1 (16 MB)" <Updating System ROM>