June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 117
2
662
General
Clearing of SMS partition
ALL
-
SYS
Clears SMS partition.
(Performs when the
service call [F106] has
occurred.)
3
666
General
/SHR partition clearing
ALL
-
SYS
Initializes the Elec-
tronic Filing.
3
667
General
/SHA partition clearing
ALL
-
SYS
Initializes the shared
folder.
3
670
General
HDD diagnostic menu dis-
play
ALL
-
SYS
Display the HDD infor-
mation
2
671
User
interface
Size indicator
ALL
0
<0-1>
SYS
0: Invalid
1: Valid
1
672
General
Initialization of department
management information
-
-
SYS
Initializing of the depart-
ment management
information
*
Key in the code and
press the [INITIAL-
IZE] button to per-
form the
initialization. If the
area storing the
department man-
agement informa-
tion is destroyed for
some reason, “Enter
Department Code”
is displayed on the
control panel even if
the department
management func-
tion is not set on. In
this case, initialize
the area with this
code. This area is
normally initialized
at the factory.
3
673
General
Trial period setting
PRT/
SCN
254
<1-60>
SYS
Sets the trial period
from 1 to 60 days. This
setting is effective only
when the default value
is “254”. Once the
default value is set, this
value is only used for a
reference.
1
678
General
Setting of banner advertis-
ing display
ALL
0
<0-1>
SYS
Sets whether or not dis-
playing the banner
advertising. The setting
contents of 08-679 and
08-680 are displayed at
the time display section
on the right top of the
screen. When both are
set, each content is dis-
played alternately.
0: Not displayed
1: Displayed
1
679
General
Banner advertising display
1
ALL
-
SYS
Maximum 27 letters
(one-byte character)
11
Setting mode (08) <e-STUDIO200L/230/280>
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......