3.1
Adjustment of Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-200))
(1)
Install the process unit into the equipment.
Note:
Note:
Do not install the toner cartridge.
(2)
While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
Fig.3-1
(3)
Key in code [200] and press the [START] button.
The display changes as follows.
Fig.3-2
Notes:
•
A indicates the controlled value of the auto-toner sensor output. Press the Up or Down button
to change the value.
•
B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
•
C indicates the latest adjustment value.
[0][5]
[POWER]
100%
TEST MODE
A3
A
[200]
[START]
230%
128
200
TEST MODE
A3
128
A
B
C