June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 113
5
20)Poor cleaning
Fig. 5-20
Defective area
Step
Check items
Prescription
Developer material
1
Using the specified developer mate-
rial?
Use the specified developer material
and toner.
Cleaner
2
Is the cleaning blade in proper con-
tact with the drum?
Check the cleaning blade.
3
Has the cleaning blade been turned
up?
Replace the cleaning blade.
Check and replace drum if neces-
sary.
Toner recovery auger
4
Is the toner recovered normally?
Clean the toner recovery auger.
Check the pressure of the cleaning
blade.
Fuser unit
5
Is the cleaning roller damaged or has
it reached its PM life?
Replace the cleaning roller.
6
Are there bubble-like scratches on
the fuser roller (94 mm pitch on the
image)?
Replace the fuser roller. Check and
adjust the temperature control circuit.
7
Has the fuser roller reached its PM
life?
Replace the fuser roller.
8
Is the pressure of the fuser roller nor-
mal?
Check and adjust the mechanism.
9
Is the setting temperature of the fuser
roller normal?
Check the setting and correct it.
08-407, 410, 411, 450, 515, 516
Feeding direction
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......