June 2004 © TOSHIBA TEC
e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 29
5
[E714]
Feed signal reception jam
Is the empty sensor working? (Perform the input check: 03-[FAX]ON/[7]/[B])
l
l
l
l
l
l
l
l
l
#
NO
1) Check if the lever of empty sensor is working normally.
2) Check if the connector of the empty sensor is disconnected.
3) Check if the connector CN5 on the RADF board is disconnected.
4) Check if the connector pins are disconnected or the harnesses are
open circuited.
5) Check if the conductor pattern on the RADF board is short circuited
or open circuited.
6) Replace the empty sensor.
7) Replace the RADF board.
YES
Replace the RADF board.
[E721]
Jam not reaching the read sensor
Are the registration roller and read roller stained?
#
YES
Clean the rollers.
NO
Is the read sensor working? (Perform the input check: 03-[FAX]ON/[7]/[G])
l
l
l
l
l
l
l
l
#
NO
1) Check if the connector of the read sensor are disconnected.
2) Check if the connector CN6 on the RADF board is disconnected.
3) Check if the connector pins are disconnected or the harnesses are
open circuited.
4) Check if the conductor pattern on the RADF board is short circuited
or open circuited.
5) Replace the read sensor.
6) Replace the RADF board.
YES
Replace the RADF board.
Summary of Contents for e-STUDIO200L
Page 6: ......
Page 12: ......
Page 400: ...e STUDIO200L 202L 230 232 280 282 ADJUSTMENT June 2004 TOSHIBA TEC 3 104 ...
Page 554: ...e STUDIO200L 202L 230 232 280 282 TROUBLESHOOTING June 2004 TOSHIBA TEC 5 124 ...
Page 678: ...e STUDIO200L 202L 230 232 280 282 REMOTE SERVICE June 2004 TOSHIBA TEC 8 24 ...
Page 702: ...e STUDIO200L 202L 230 232 280 282 WIRE HARNESS CONNECTION DIAGRAMS June 2004 TOSHIBA TEC 10 2 ...
Page 707: ......
Page 708: ......