Hardware Installation
Commander i+ Product Service Manual - Issue 2
Page 3-7
Straight Bus
•
Maximum bus length: 200 metres
•
Terminations: 100 ohms at the ends of the bus only (2 terminations
only)
•
No more than four keystations / AFUs within any 15 metre segment
of cable.
•
Master stations can be anywhere on the bus.
RLS
RLS
RLS
RLS
AFU
100 ohm
100 ohm
200 m
Bus Socket
Bus Wiring (0.5 mm diameter)
Station Bus Cord
Legend