Advanced-control timers (TIM1)
RM0365
515/1080
DocID025202 Rev 7
20.4 TIM1
registers
Refer to for a list of abbreviations used in register descriptions.
20.4.1
TIM1 control register 1 (TIMx_CR1)
Address offset: 0x00
Reset value: 0x0000
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Res.
Res.
Res.
Res.
UIFRE
MAP
Res.
CKD[1:0]
ARPE
CMS[1:0]
DIR
OPM
URS
UDIS
CEN
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Bits 15:12 Reserved, must be kept at reset value.
Bit 11
UIFREMAP
: UIF status bit remapping
0: No remapping. UIF status bit is not copied to TIMx_CNT register bit 31.
1: Remapping enabled. UIF status bit is copied to TIMx_CNT register bit 31.
Bit 10 Reserved, must be kept at reset value.
Bits 9:8
CKD[1:0]
: Clock division
This bit-field indicates the division ratio between the timer clock (CK_INT) frequency and the
dead-time and sampling clock (t
DTS
)used by the dead-time generators and the digital filters
(ETR, TIx),
00: t
DTS
=t
CK_INT
01: t
DTS
=2*t
CK_INT
10: t
DTS
=4*t
CK_INT
11: Reserved, do not program this value
Bit 7
ARPE
: Auto-reload preload enable
0: TIMx_ARR register is not buffered
1: TIMx_ARR register is buffered
Bits 6:5
CMS[1:0]
: Center-aligned mode selection
00: Edge-aligned mode. The counter counts up or down depending on the direction bit
(DIR).
01: Center-aligned mode 1. The counter counts up and down alternatively. Output compare
interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set
only when the counter is counting down.
10: Center-aligned mode 2. The counter counts up and down alternatively. Output compare
interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set
only when the counter is counting up.
11: Center-aligned mode 3. The counter counts up and down alternatively. Output compare
interrupt flags of channels configured in output (CCxS=00 in TIMx_CCMRx register) are set
both when the counter is counting up or down.
Note: It is not allowed to switch from edge-aligned mode to center-aligned mode as long as
the counter is enabled (CEN=1)
Bit 4
DIR
: Direction
0: Counter used as upcounter
1: Counter used as downcounter
Note: This bit is read only when the timer is configured in Center-aligned mode or Encoder
mode.