background image

 

 
 

Crestron

 C2N-NPA8 

Network Poll Accelerator 

Operations Guide

 

 

Summary of Contents for C2N-NPA8

Page 1: ...Crestron C2N NPA8 NetworkPollAccelerator Operations Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2004 Crestron Electronics Inc ...

Page 3: ...out a Program 18 Programming Software 19 Earliest Version Software Requirements for the PC 19 Serial Connection Between the Control System and C2N NPA8 20 Ethernet Connection Between the Control System and C2N NPA8 21 Uploading and Upgrading 22 Communication Settings 22 Uploading a SIMPL Windows Program 24 Updating the Operating System 26 Problem Solving 27 Troubleshooting the C2N NPA8 27 Further ...

Page 4: ......

Page 5: ...mmunicates with select 2 Series control systems via high speed serial or 10 100 Base T Ethernet refer to Compatible Control Systems on page 6 for a list of compatible control systems Console function to configure device settings and monitor diagnostics via DB 9 RS 232 connector Each Cresnet ID can be viewed with the Network Analyzer Placing a large amount of Cresnet devices on a control system can...

Page 6: ...ovides 24V input from power supply or powered segment and 24V output to segment on C2N NPA8 One per segment 32 Cresnet 4 position mini terminal block connectors divided over 8 segments 1 RJ45 10 100 Base T Ethernet port 1 DB9F PC Interface for console functions 1 DB9F Interface for high speed serial connection to control system Cresnet Devices Supported 252 1 Firmware V3105 CUZ or later Control Sy...

Page 7: ...closure with labeling on the front panel Refer to the following illustrations for a detailed view C2N NPA8 Physical View C2N NPA8 Physical Views 12 25 in 31 12 cm 3 00 in 7 62 cm 5 19 in 13 18 cm 4 00 in 10 16 cm 12 75 in 32 39 cm 13 25 in 33 66 cm 3 42 in 8 69 cm Operations Guide DOC 6087A Network Poll Accelerator C2N NPA8 3 ...

Page 8: ...B For more details refer to Power Connections on page 12 CAUTION Use only Crestron power supplies for Crestron equipment Failure to do so could cause equipment damage or void the Crestron warranty LAN An 8 position RJ45 port is used for an Ethernet connection to a control system with Ethernet capabilities Refer to the following table for the Ethernet connector signals and use an appropriate cable ...

Page 9: ...e DB9 Connector 6 7 8 9 1 2 3 4 5 Male DB9 Connector NOTE DTR pin 4 and DSR pin 6 are not normally used COM This DB9 female bi directional serial port is used for high speed serial communication between a control system and the C2N NPA8 Use with a DB9 straight through cable Crestron cable number CNSP 587 or equivalent NOTE Crestron has successfully tested 50 foot serial cable runs without loss of ...

Page 10: ...with the C2N NPA8 The following table lists 2 series control systems that are currently available as of this writing that are compatible with the C2N NPA8 as well as the communication methods that can be used Processor Compatibility PROCESSOR SERIAL ETHERNET AV2 YES 1 YES 4 C2N DVP4DI NO YES CNX DVP4 NO YES CP2 YES 3 NO CP2E YES 3 YES MC2E YES 3 YES MC2W YES 3 NO MP2 YES 3 NO MP2E YES 3 YES PAC2 N...

Page 11: ...nstallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a ci...

Page 12: ...t PF Power factor of entire run or chain R L x PF 40 000 Where The required wire gauge should be chosen such that the resistance value is less than the value calculated in the resistance equation Refer to the following table Wire Gauge Values RESISTANCE R WIRE GAUGE 4 16 6 18 10 20 15 22 13 Doubled CAT5 8 7 Tripled CAT5 NOTE When daisy chaining Cresnet units strip the ends of the wires carefully t...

Page 13: ...current from equipment under any external load conditions shall not exceed a current limit that is suitable for the minimum wire gauge used in interconnecting cables The ratings on the connecting unit s supply input should be considered to prevent overloading the wiring Hookup Connections for the C2N NPA8 10 100 BASE T ETHERNET TO CONTROL SYSTEM CONSOLE TO PC HIGH SPEED SERIAL TO CONTROL SYSTEM FR...

Page 14: ...egment B etc Since the Cresnet network is polled by the control system in numeric order the control system will talk to different segments allowing each segment to process commands that overlap instead of having to wait for the completion of one command before going on to the next command Example The following example is provided to show how a large amount of network devices may be connected to th...

Page 15: ...xample NOTE 24 VDC power must be supplied to the C2N NPA8 by the PWR connector on segment A or B The control system must communicate with the poll accelerator via serial or Ethernet communications Operations Guide DOC 6087A Network Poll Accelerator C2N NPA8 11 ...

Page 16: ...ach power segment from the C2N SPWS300 to a segment on the C2N NPA8 as shown in the following diagram each segment on the C2N NPA8 can be activated or deactivated by controlling the C2N SPWS300 through additional programming in the control system program NOTE If the C2N SPWS300 is being used to power each segment on the C2N NPA8 power must always be applied to segment A or segment B on the C2N NPA...

Page 17: ...C2N NPA8 can also be connected to compatible control systems that are equipped with an Ethernet port Refer to TCP IP Communications Between a Control System and the C2N NPA8 on page 14 NOTE For a list of control systems that are compatible with the C2N NPA8 refer to Compatible Control Systems on page 6 C2N NPA8 Control System Communications The C2N NPA8 can communicate with a control system over s...

Page 18: ...mmercially available cables are acceptable Refer to COMPUTER on page 5 for pinout details NOTE For laptops and other PCs without a built in RS 232 port Crestron recommends the use of PCMCIA cards rather than USB to serial adapters If a USB to serial adapter must be used Crestron has tested the following devices with good results I O Gear GUC232A Keyspan USA 19QW Discontinued Results may vary depen...

Page 19: ...tron e Control Reference Guide Doc 6052 The latest version is available as a PDF on the Crestron website www crestron com 1 From the Viewport menu click Functions Set Control System IP Information 2 Enter the IP address IP Mask Router IP address Hostname and Domain name in the applicable fields and click OK 3 After saving the IP address an entry must be added to the C2N NPA8 IP table to enable com...

Page 20: ...ccessible to the control system for communication with the C2N NPA8 NOTE If a control system program uses a TCP IP Client symbol or TCP IP Server symbol port number 41791 cannot be specified for either symbol if a C2N NPA8 is in the control system program NOTE The default port number assigned by Viewport should not be changed when configuring the IP tables on the control system and the C2N NPA8 NO...

Page 21: ...P as the connection type and enter the IP address of the C2N NPA8 Click OK to connect to the C2N NPA8 over TCP IP Port Settings Window To verify communication click Diagnostics Establish Communications Find Rack This should display a window that gives the IP address and port number If communications cannot be established between the C2N NPA8 and a control system refer to Troubleshooting Communicat...

Page 22: ... to the SIMPL Windows help file and use the index to search for Network Analyzer Adding a C2N NPA8 Without a Program If a control system has been rebooted and it does not have a program that contains a C2N NPA8 it must be told via console command that a C2N NPA8 is present If using serial communications open Viewport while connected to a control system and type NPA ADD PORT Y Where Y is the letter...

Page 23: ...ovided with the software NOTE The following are acceptable file extensions for programs that include a C2N NPA8 developed for specific control system types smw projectname smw source file spz projectname spz compiled file for 2 series usp projectname usp source code module for SIMPL ush projectname ush compiled SIMPL file umc projectname umc user macro NOTE In the following the PRO2 control system...

Page 24: ...A8 to a 2 series control system is as easy as dragging and dropping the device into the appropriate device slot in the 2 Series system tree Serial Connection Between the Control System and C2N NPA8 If the C2N NPA8 is to be connected to a control system via serial communications perform the following In Configuration Manager drag the C2N NPA8 from the Serial Drivers General folder of the Device Lib...

Page 25: ...Compatible Control Systems on page 6 NOTE An IP table entry for the control system must exist on the C2N NPA8 s IP table Refer to Configuring for TCP IP Communications on page 15 for more information Setting the IP Information in Device Settings Double click the C2N NPA8 icon to open the Device Settings window This window displays the C2N NPA8 device information Select the IP Net Address tab to ch...

Page 26: ...ions are accessed through the commands and options in the Viewport menus Therefore for its effectiveness as a support and diagnostic tool the Crestron Viewport may be preferred over development tools when uploading programs and projects The following sections define how one would upload a SIMPL Windows program containing a C2N NPA8 or upgrade the firmware of the C2N NPA8 However before attempting ...

Page 27: ...select Setup Communications settings alternatively press Alt D to open the Port Settings window Setup Communications Settings Command 3 Select RS 232 as the connection type Verify that an available COM port COM 1 is shown after this step is selected and that all communication parameters and necessary options from the Port Settings window are selected as shown after this step Click the OK button to...

Page 28: ...e respective Operations Guide for the control system Uploading a SIMPL Windows Program A control system source file has the extension smw A compiled SIMPL Windows file has the extension spz for a 2 Series control system Once communication with the control system has been established a SIMPL Windows program containing a C2N NPA8 can be uploaded to the control system using SIMPL Windows or the Crest...

Page 29: ... If it does contain SIMPL modules then the SIMPL Program s check box will also be enabled Select one or both check boxes and then click Send Program to begin the transfer NOTE Refer to the respective Operations Guide for the control system for details about the other fields shown on the Send Program window Send Program Window 4 To verify that the program has been transferred successfully select Di...

Page 30: ... happens rename the file removing the zip extension NOTE Even though the C2N NPA8 uses a CUZ file it cannot be loaded with a SIMPL Windows or SIMPL program To upload the new cuz to the C2N NPA8 1 Open Viewport and connect to the C2N NPA8 over a serial from the COM port on the PC to the COMPUTER port on C2N NPA8 or TCP IP connection as described in Communication Settings on page 22 2 Select File Tr...

Page 31: ... the segment is connected to a powered segment ERR LED illuminates Hardware failure software failure or programming error Verify that the hardware configuration matches software configuration Poll the network F4 from the Viewport check error log for SIMPL SIMPL program reload errors Used wrong serial port Verify that a Poll Accelerator compatible port is used if using serial communications refer t...

Page 32: ...inate duplicates etc 5 Clear the error log If the ERR LED illuminates again unplug the unit and reapply power after a few seconds If the LED illuminates again or if communication still cannot be established contact Crestron customer service Troubleshooting Non Functioning Units If after reviewing the troubleshooting chart on page 27 the C2N NPA8 is still not functioning reinstall the operating sys...

Page 33: ...leshooting the unit contains Crestron s patent pending network analyzer to continuously monitor the integrity of the Cresnet network for wiring faults and marginal system performance or other network errors For more information on how to use the network analyzer refer to the SIMPL Windows help file and use the index to search for Network Analyzer NOTE The Network Analyzer can be used when directly...

Page 34: ...n also log onto the online help section of the Crestron website www crestron com to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the C2N NPA8 additional information may be made available as manual updates These ...

Page 35: ...ands data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Software is designed as a software development and customization tool As such Crestron cannot and does not guarantee any results of use of the Software or that the Software will operate error free and Yo...

Page 36: ...inety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its option repair or replace or refund the license fee for any Software found defective by Crestron if notified by you within the warranty period The foregoing remedy shall be your exclusive remedy for ...

Page 37: ...nt lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has bee...

Page 38: ...Network Poll Accelerator Crestron C2N NPA8 34 Network Poll Accelerator C2N NPA8 Operations Guide DOC 6087A This page is intentionally left blank ...

Page 39: ...Crestron C2N NPA8 Network Poll Accelerator This page is intentionally left blank Operations Guide DOC 6087A Network Poll Accelerator C2N NPA8 35 ...

Page 40: ...Crestron Electronics Inc Operations Guide DOC 6087A 15 Volvo Drive Rockleigh NJ 07647 06 04 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: