DocID025202 Rev 7
994/1080
RM0365
Controller area network (bxCAN)
CAN receive FIFO mailbox data length control and time stamp register
(CAN_RDTxR) (x = 0..1)
Address offsets: 0x1B4, 0x1C4
Reset value: 0xXXXX XXXX
All RX registers are write protected.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
TIME[15:0]
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FMI[7:0]
Res.
Res.
Res.
Res.
DLC[3:0]
r
r
r
r
r
r
r
r
r
r
r
r
Bits 31:16
TIME[15:0]
:
Message time stamp
This field contains the 16-bit timer value captured at the SOF detection.
Bits 15:8
FMI[7:0]
:
Filter match index
This register contains the index of the filter the message stored in the mailbox passed
through. For more details on identifier filtering refer to
Section 31.7.4: Identifier filtering on
-
Filter Match Index
paragraph.
Bits 7:4 Reserved, must be kept at reset value.
Bits 3:0
DLC[3:0]
:
Data length code
This field defines the number of data bytes a data frame contains (0 to 8). It is 0 in the case