Scan by Channel Banks
1)
Press the “SCAN” button.
2)
If the frequency is displayed, press the “CHAN” button to display
six dashes.
3)
If six dashes are already displayed, type in the desired banks to
scan. Example: By entering “0134” the radio will scan through
banks 0, 1, 3, and 4. If an empty bank is selected, the unit will first
try to scan through that bank; however the bank will be eliminated
once it is determined the bank is vacant.
Note: If there are no keys pressed within four seconds, the unit will begin
scanning automatically from the original channel on display at the
start of the function.'
4)
Press the “SCAN” button again to begin scanning.
5)
To change the direction of the scan , or to step through the scan
banks, press the “Up” or “Down” arrow.
6)
To allow the pause on detection, press the squelch by pressing “3”
or “SQL.”
7)
To stop the scan, simply press the “SCAN” button.
13.11
Changing Frequency or Channel Scan Rates
Separate scan rates are available for frequency or channel scanning. You must be
in the frequency scan mode to set frequency scan rate and in channel scan to set
channel scan rate. If the unit is not scanning, the function will change the rate of
the last scan mode performed.
Change Frequency Scan Rate (In Frequency Scan Mode)
1)
Press the “SHIFT/FUNC” button.
2)
Press the “SCAN” button.
3)
Press the “Up” or “Down” arrow to change the rate to the following:
a)
1 step per second
|
b)
2 steps per second
||
c)
5 steps per second
|||
4)
This function will automatically time out after four seconds.