Unload Frequency Limits
In order for the SG-2000 to resume normal frequency scanning (scanning up or
down anywhere in its range), it is necessary to unload the scan brackets. To do
this, the following sequence is used.
1)
Press “PRGM.”
2)
Press “SCAN.”
3)
Press “CHAN.”
4)
Display will show [ LC : - - 2 2 ] (If Channel 22 is lower
limit.)
5)
Press “SHIFT/FUNC.”
6)
Press “7” (the delete key in the SHIFT/FUNC mode.)
7)
Press “CHAN.”
8)
Display will show [ L C : - - 2 3 ] (If Channel 23 is upper limit.)
9)
Press “SHIFT/FUNC.”
10)
Press “7” (the delete key in the SHIFT/FUNC mode.)
11)
Press “PRGM” to execute the function and exit the programming mode.
Scan by Channels
1)
Press “SCAN.”
2)
Press “CHAN.” (If dashes appear, press CHAN again.)
Note: If there are no keys pressed within 4 seconds, the unit will start scanning
automatically from the original channel on display at the start of the
function.
3)
To change the direction of the scan or to step through the channels,
press the respective “Up” or “Down” arrow.
4)
To allow the pause on detection, press the squelch by pressing “3”
or “SQL.”
5)
To change from scanning the ITU channels to the SITOR channels
or visa versa, set the unit in VOC or TLX mode respectively by
engaging the “2” or “VOC/TLX” button.
6)
To stop the scan, simply press the “SCAN” button.