Rev. 5.00, 12/03, page 498 of 1088
13.3.3
Data Format
Normal Transfer Mode: Figure 13-3 shows the smart card interface data format in the normal
transfer mode. In reception in this mode, a parity check is carried out on each frame. If an error is
detected an error signal is sent back to the transmitting end, and retransmission of the data is
requested. If an error signal is sampled during transmission, the same data is retransmitted.
Ds
D0
D1
D2
D3
D4
D5
D6
D7
Dp
When there is no parity error
Transmitting station output
Ds
D0
D1
D2
D3
D4
D5
D6
D7
Dp
When a parity error occurs
Transmitting station output
DE
Receiving station
output
Legend:
Ds
: Start bit
D0 to D7 : Data bits
Dp
: Parity bit
DE
: Error signal
Figure 13-3 Smart Card Interface Data Format
Summary of Contents for H8S/2318 series
Page 2: ......
Page 6: ...Rev 5 00 12 03 page vi of xxx...
Page 12: ...Rev 5 00 12 03 page xii of xxx...
Page 30: ...Rev 5 00 12 03 page xxx of xxx...
Page 54: ...Rev 5 00 12 03 page 24 of 1088...
Page 98: ...Rev 5 00 12 03 page 68 of 1088...
Page 128: ...Rev 5 00 12 03 page 98 of 1088...
Page 138: ...Rev 5 00 12 03 page 108 of 1088...
Page 168: ...Rev 5 00 12 03 page 138 of 1088...
Page 212: ...Rev 5 00 12 03 page 182 of 1088...
Page 324: ...Rev 5 00 12 03 page 294 of 1088...
Page 436: ...Rev 5 00 12 03 page 406 of 1088...
Page 546: ...Rev 5 00 12 03 page 516 of 1088...
Page 580: ...Rev 5 00 12 03 page 550 of 1088...
Page 822: ...Rev 5 00 12 03 page 792 of 1088...
Page 876: ...Rev 5 00 12 03 page 846 of 1088...
Page 901: ...Rev 5 00 12 03 page 871 of 1088 A 2 Instruction Codes Table A 2 shows the instruction codes...
Page 1121: ...H8S 2319 Group H8S 2318 Group Hardware Manual REJ09B0089 0500O...