Appendix M - Homologation for Brazil
Polycom®, Inc.
1070
Flag name: H323_TIMERS_SET_INDEX
Flag description: Enables or disables H.323 index timer according to standard or proprietary H.323 protocol.
Section CS_MODULE_PARAMETERS
Possible values:
0
- Sets the H.323 index timer to Polycom proprietary (flag default setting)
1
- Sets the H.323 index timer based on the H.323 Standard recommendation. For homologation and
certification testing, this flag must be set to 1.
Flag name: DISABLE_DUMMY_REGISTRATION
Flag description: Enables or disables SIP dummy registration on the domain.
Flag Section: MCMS_PARAMETERS_USER
Possible values:
NO
- Disables SIP dummy registration (flag default setting).
YES
- Enables SIP dummy registration. For homologation and certification testing, the flag must be set to
YES
.
Summary of Contents for RealPresence RMX 4000