background image

CMU200/XXXx2.485x1.FOTx39 – 28

CMU 200 / HACx2 . 485x1 . FOTx39 – 12

CMU 200 / MDCx2 . 485x1 . FOTx39 – 12

 

Company:

Device:  

Document: 

Code:

Version:

Date:

Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 V1

28.05.2015

CMU 200

User manual

Summary of Contents for CMU 200 / HACx2 . 485x1 . FOTx39 - 12

Page 1: ...2 485x1 FOTx39 28 CMU 200 HACx2 485x1 FOTx39 12 CMU 200 MDCx2 485x1 FOTx39 12 Company Device Document Code Version Date Ediseja 21 CMU200 XXXx2 485x1 FOTx39 User manual CMUMU203 V1 28 05 2015 CMU 200...

Page 2: ...PORTS CONFIGURATION 8 3 3 2 RS485 INTERFACE BOARD 8 3 3 3 MULTIMODE FIBER OPTIC INTERFACE BOARD 11 4 SCHEMATIC 13 5 INSTALLATION 14 5 1 INSTALLATION 14 6 COMMISSIONING MAINTENACE 15 6 1 COMMISSIONING...

Page 3: ...ns or comments related to this product please contact us on Ediseja 21 d o o Drenov Gric 175 1360 Vrhnika Slovenia EU Tel 00 386 51 643 411 051 643 411 Email grega flander ediseja21 com www ediseja21...

Page 4: ...d safe operation of the described devices This paper is intended for technically qualified personnel Warning Hazardous voltage is present inside the device during operation Disregarding of safety rule...

Page 5: ...ect it from power supply Send it to the manufacturer for inspection Warning Connect to earth before attaching power supply Company Device Document Code Version Date Page Ediseja 21 CMU200 XXXx2 485x1...

Page 6: ...oftware is application dependent and allows different hardware configurations Software s task is switching between communication ports and allows almost any combination between them 2 1 2 HARDWARE CMU...

Page 7: ...station batteries Additionaly it can be also connected to standard AC voltages This device is intended for use in cubicles and cabinets in all kinds of power production transmission and distribution s...

Page 8: ...8 39 40 Inter FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM 3 3 2 RS485 INTERFACE BOARD Description Single galvanically isolated half duplex RS485 port with Phoenix 3 pin screw connector...

Page 9: ...s no voltage difference between those pins and some device do not work correctly On this port board so called true fail safe RS485 chip is used so board works correctly without stabilisation at invali...

Page 10: ...required are used please note it in order NOTE If there are problems with communication try using higher speed setting Some manufacturer have different markings for B and A line Try to switch A and B...

Page 11: ...ic Hardware settings For proper functioning of that board optic logic must be set Fiber optic logic settings Switch SW1 Light in idle state 1 2 3 4 Positive logic OFF OFF ON OFF ON Negative logic ON O...

Page 12: ...CMU 200 User manual Page Company Device Document Code Version Date 12 Ediseja 21 CMU200 XXXx2 485x1 FOTx39 User manual CMUMU203 V1 28 05 2015 Picture 6 Multimode fiber optic interface board appearance...

Page 13: ...SCHEMATIC 4 SCHEMATIC Company Device Document Code Version Date Page Ediseja 21 CMU200 XXXx2 485x1 FOTx39 User manual CMUMU203 V1 28 05 2015 13 Picture 7 Schematic...

Page 14: ...temperature must be observed Check the device for damage at unpacking If device is damaged it must not be installed but It should be send to the manufacturer for repair The device should not be opene...

Page 15: ...assembled Device must be used as described No modifications of the device should be made Attach ground wire before attaching power supply Device must be grounded during operation Check if the power s...

Page 16: ...peed Interface type 5 19200 115200 BAUD Interface type M 4800 38400 BAUD Interface type L 300 2400 BAUD Number of ports 1 Distance up to 1200 m Isolation 1000 V DC Connector type MSTB Phoenix 3pin Ter...

Page 17: ...lowest interface defines device s maximum speed Device Weight 6 kg Dimensions see picture W H D 19 rack 3U 133 mm 154 mm connectors Temperature range 0 C to 55 C Humidity operating up to 95 noncondens...

Page 18: ...CMU 200 User manual 8 DIMENSIONS Page Company Device Document Code Version Date 18 Ediseja 21 CMU200 XXXx2 485x1 FOTx39 User manual CMUMU203 V1 28 05 2015 Picture 8 Dimensions...

Page 19: ...umber of interfaces in CMU 200 is 40 Each 23R and 2RI interface must be treated as two interfaces Function three ports star coupler up to 13 groups 2 1 on 1 converter up to 20 groups 7 40 port star co...

Page 20: ...h naprav d o o Drenov Gric 175 1360 Vrhnika Slovenia EU Tel 00 386 51 643 411 051 643 411 grega flander ediseja21 com www ediseja21 com Page Company Device Document Code Version Date 20 Ediseja 21 CMU...

Reviews: