IP Network Services
Polycom, Inc.
517
Configuration Requirements
LAN Redundancy is disabled by default and is enabled by changing the
LAN_REDUNDANCY
system flag
to
YES
and connecting the appropriate LAN cables to the LAN ports on the Collaboration Server as follows:
RealPresence Collaboration Server (RMX) 1500
»
Connect the additional LAN cable to
LAN 1
port on the RTM IP.
RealPresence Collaboration Server 1800
»
Connect the additional LAN cable to
LAN 2
port on the rear panel of the Collaboration Server 1800.
RealPresence Collaboration Server (RMX) 2000
●
Connect the additional LAN cable to
LAN 1
port on the RTM LAN.
●
I
n the
Setup> System Configuration
>
System Flags
dialog box, add the flag
RMX2000_RTM_LAN
and set it to
YES
to activate the installed RTM LAN card.
●
On the RealPresence Collaboration Server (RMX) 2000, LAN Redundancy can be enabled
simultaneously with Multiple Networks. To enable the Multiple Networks option, set the
MULTIPLE_SERVICES
flag to
YES
.
●
A
system reset is required when adding the
RMX2000_RTM_LAN
flag.
RealPresence Collaboration Server (RMX) 4000
●
Connect the additional LAN cable to
LAN 1
port on the RTM LAN.
●
On the RealPresence Collaboration Server (RMX) 4000, LAN Redundancy can be enabled
simultaneously with Multiple Networks. To enable the Multiple Networks option, set the
MULTIPLE_SERVICES
flag to
YES
.
●
If required, reset the Collaboration Server.
On all systems:
●
LAN Redundancy can be disabled by setting the
LAN_REDUNDANCY
System Flag to
NO
.
●
If the
LAN_REDUNDANCY
System Flag value set to
NO,
the LAN 2 port must be connected to the
IP network.
Hardware Monitor Indications
When LAN Redundancy is enabled on the Collaboration Server, LAN 2 port is
Active.
With LAN
redundancy, when LAN LEDs are lit they indicate that a physical connection of the cables is present but
On a RealPresence Collaboration Server (RMX) 2000, one RTM LAN card is required.
For more information see the
RealPresence Collaboration Server (RMX) 2000 Hardware Guide
,
Installing or Replacing the RTM LAN
.
On the RMX 1500/2000/4000, full media redundancy is supported if only one IP Network Service is
defined per media card.
Summary of Contents for RealPresence RMX 4000
Page 135: ...Defining SVC and Mixed CP and SVC Conference Profiles Polycom Inc 104 12 Click the IVR tab ...
Page 468: ...Conference and Participant Monitoring Polycom Inc 437 ...
Page 578: ...Network Security Polycom Inc 547 3 Define the following fields ...
Page 992: ...Appendix D Ad Hoc Conferencing and External Database Authentication Polycom Inc 961 ...