![background image](http://html.mh-extra.com/html/omron/sysmac-ny512-1300/sysmac-ny512-1300_user-manual_742451330.webp)
12 SNMP Agent
12-6
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
Interfaces
Group
Subtree name
Standard [(
identifier
)
attribute
]
Support
Implementation
specifications
ifNumber
(1) RO
The number of network interfaces.
Sup-
ported.
3
ifTable
(2) NA
Interface entity table
---
ifEntry
(1) NA
Row data for interface information
The index is
ifIndex
.
---
ifIndex
(1) RO
A number used to identify the interface.
Sup-
ported.
1 to 3
ifDescr
(2) RO
Information related to the interface (includes man-
ufacturer name, product name, and hardware
interface version).
Sup-
ported.
1. Loop Back
2. 10/100/1000M
Gigabit Ethernet
Port
3. Internal Network
Port
ifType
(3) RO
The type of interface classified according to the
physical/link layer protocol directly under the net-
work layer of the protocol stack.
Sup-
ported.
ethernet-csmacd(6)
ifMtu
(4) RO
MTU value
The maximum size (in octets) of datagrams that
can be sent and received through this interface.
Sup-
ported.
1,500
ifSpeed
(5) RO
Estimated bandwidth
If a stable, accurate value cannot be obtained for
the bandwidth, a nominal value is set instead.
Sup-
ported.
10000000/
100000000/
1000000000
ifPhysAddress
(6) RO
MAC address
The physical address under the network layer of
the interface.
Sup-
ported.
The MAC address of
the EtherNet/IP port.
ifAdminStatus
(7) RW
The preferred status of the interface.
You cannot send normal packets in the testing state.
up(1)
down(2)
testing(3)
Sup-
ported.
According to the
standard.
ifOperStatus
(8) RO
The current status of the interface.
You cannot send normal packets in the testing state.
up(1)
down(2)
testing(3)
Sup-
ported.
According to the
standard.
Summary of Contents for Sysmac NY512-1300