The bandwidth usage for the device can be displayed from the EtherNet/IP Connection Setting Tab
Page.
This value is for when multicast filtering is used.
Precautions for Correct Use
Precautions for Correct Use
In the Device Bandwidth Dialog Box, you can only check the bandwidth being used for the Ether-
Net/IP connections from one originator device to its target devices.
The actual bandwidth used for the EtherNet/IP network must be calculated by taking into
account of all bandwidths used on the EtherNet/IP network (i.e., bandwidths used for connec-
tions for the other devices in the EtherNet/IP network than the one given on the dialog box must
be included into the calculation).
Procedure
Click the
Device Bandwidth
Button in the EtherNet/IP Connection Setting Tab Page for the target
device.
Additional Information
You can specify a value in
Set Packet Interval (RPI) for All Connections
and click the
Update
Button to change packet interval (RPI) values set in the connection settings for all target devices
to the specified value.
Checking the Device Bandwidth Usage
Menu
Description
PPS
Gives the bandwidth used for each target device and total bandwidth used
for all target devices.
Set Packet Interval (RPI) for All
Connections
Changes all Packet Interval (RPI) values for all target devices.