14-5
14 Checking Communications Status of Network and Troubleshooting
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
14-
1 Device
Mon
itorin
g
o
n
th
e Net
w
o
rk Con
fig
urato
r
14
14-
1-2 S
tatus Disp
lays
of the Device Monitor
ing
Connection Tab Page
Information about the target node that acts as the originator is displayed. If all tag data link connec-
tions to the node are established and normal, this information is displayed in blue. However, if any
connection is broken it is displayed in red. However, this information is displayed in gray if the con-
nection to the node is stopped. In addition, the
Connection Status
Area shows the current status of
each connection that is set as the originator. This information can be used to identify the cause of
tag data link errors. Refer to
14-2 Connection Status Codes and Troubleshooting
for details on the
connection status.