1-11
1 Introduction
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
1
-3 Bu
ilt-in Eth
erNet/IP Po
rt
1
1
-3-2
P
a
rt Names and F
unction
s
The following provides information on indicators associated with the built-in EtherNet/IP port on NY-
series Controllers.
LINK/ACT/10/100/1000
•
LINK/ACT indicator: This shows the Ethernet communications status.
•
10/100/1000 indicator: This shows the baud rate status.
Additional Information
When the built-in EtherNet/IP port is set to disable, all the indicators will not light. Refer to
for the information on setting the built-in EtherNet/IP port.
Indicators (LEDs)
Indicator
Color
Status
Operating status
LINK/ACT
---
Not lit
Link not established.
•
The cable is not connected.
•
The power supply is OFF or was reset.
Yellow
Flashing
Data communications in progress after establishing link.
Lit
Links established.
10/100/1000
--
Not lit
Link established with a baud rate of 10 Mbps, or link not
established.
Green
Lit
Link established with a baud rate of 100 Mbps.
Orange
Lit
Link established with a baud rate of 1000 Mbps.
10/100/1000
LINK/ACT