8 CIP Message Communications
8-28
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
Precautions for Correct Use
Precautions for Correct Use
If
Execute
changes back to FALSE before
Done
changes to TRUE,
Done
stays TRUE for only
one task period. (Example 1)
If you want to see if
Done
is TRUE at any time, make sure to keep
Execute
TRUE until you con-
firm that
Done
is TRUE. If
Execute
is TRUE until
Done
changes to TRUE,
Done
stays TRUE
until
Execute
changes to FALSE. (Example 2)
This section describes the response codes stored in the output variable
ErrorIDEx
if an error occurs
during the execution of a CIP message communications instruction.
As response codes, general codes are stored in the
ErrorIDEx
output variable (DWORD data) after
execution of a CIP communications instruction is completed. If an additional code is added, the addi-
tional code is also stored.
8-2-10 Response Codes
General Status Codes
General sta-
tus code (hex)
Status name
Description of status
00
Success
Service was successfully performed by the object speci-
fied.
01
Connection failure
A connection related to service failed along the connection
path.
02
Resource unavailable
Resources needed for the object to perform the requested
service were unavailable.
03
Invalid parameter value
See Status Code 20 hex.
04
Path segment error
The path segment identifier or the segment syntax was
not understood by the processing node. Path processing
stops when a path segment error occurs.
05
Path destination unknown
The path is referencing an object class, instance, or struc-
ture element that is not known or is not contained in the
processing node. Path processing stops when a Path
Destination Unknown Error occurs.
06
Partial transfer
Only part of the expected data was transferred.
07
Connection lost
The message connection was lost.
Execute
Done
Execute
Done
Busy
(Executing)
Busy
(Executing)
Changes to
FALSE in next
task period.
When
Execute
changes to
FALSE,
Done
returns to FALSE.
Example 1
Example 2
General status code (1 byte)
Additional code (1 word)
ErrorIDEx
31
23
16
15
0
24
Summary of Contents for Sysmac NY512-1300