7-55
7 Tag Data Link Functions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
7-
2 S
e
tti
ng
T
ag
Da
ta
Li
n
ks
7
7-2
-9 Dow
nloa
ding T
ag D
at
a Link Par
ameter
s
3
Click the
Yes
Button to download the tag data link parameters to the EtherNet/ IP Unit. The fol-
lowing dialog box is displayed if any of the Controllers is not in PROGRAM mode.
If the
Download after changed to Program mode
Button is clicked, all Controllers are
changed to PROGRAM mode and the parameters are downloaded. Confirm safety for all con-
trolled equipment before you change the Controllers to PROGRAM mode. You can restore the
operating modes after the parameters are downloaded.
You can click the
Download with Current mode
Button to download the parameters even
when one or more Controllers is in RUN mode. The
Download with Current mode
Button is
disabled if the EtherNet/IP Unit does not support this function (e.g., revision 1 of CJ1W-EIP21 or
CS1W-EIP21).
During the download, the following progress monitor is displayed to show the progress of the
download.
If the operating mode of one or more Controllers was changed to download the parameters, you
can return the Controllers to the previous operating modes. If the
No
Button is clicked, the Con-
trollers remain in PROGRAM mode.
4
The following dialog box is displayed to show that the download was completed.