7-65
7 Tag Data Link Functions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
7-
2 S
e
tti
ng
T
ag
Da
ta
Li
n
ks
7
7-2
-13 Clear
ing th
e Device Para
meters
3
Select
Device - Reset
. You can also right-click the icon and select
Reset
from the popup menu.
4
The following dialog box is displayed.
Yes Button:
The following dialog box is displayed.
Select the
Initialize tag data link configuration, and then emulate cycling power
Option and then click
the
OK
Button.
Precautions for Correct Use
Precautions for Correct Use
The Controller is not restarted. Both the built-in EtherNet/IP port and internal port are reset.
No Button:
The tag data link settings will not be cleared and the built-in EtherNet/IP port and internal port will
not be reset.