1 Introduction
1-14
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
The two built-in EtherNet/IP ports on the NY-series Controller both have the IP routing function. The IP
routing function sends IP packets to other network segments based on the routing information set in the
IP router table.
To communicate with devices on other network segments, you must set the IP router table and default
gateway settings for the NY-series Controller and each device on the network appropriately for your
network configuration.
Precautions for Correct Use
Precautions for Correct Use
•
You cannot create tag data links between multiple Controllers using IP routing on the NY-
series Controller.
The following figure is an example of communications between the Controller in an NY-series Industrial
PC and an NJ-series Controller on a different network segment. Here, you need to set the route infor-
mation for communicating via the built-in EtherNet/IP port on the NX-series Controller in the IP router
table and default gateway settings for the Controller in an NY-series Industrial PC.
The NY-series Controller provides the following functions related to the IP routing function.
Refer to
for the procedure to set each function.
1-4-3
IP Routing
IP router
table
NY-series Industrial PC
Windows
Controller
Internal
communications
network
Built-in EtherNet/IP port
Built-in EtherNet/IP port
NX-series
Controller
NJ-series
Controller
EtherNet/IP
EtherNet/IP
IP router
table
IP address:10.1.3.1/24
Netwrok address:10.1.3.0/24
Netwrok address:10.1.2.0/24