![Omron Sysmac NY512-1300 User Manual Download Page 204](http://html.mh-extra.com/html/omron/sysmac-ny512-1300/sysmac-ny512-1300_user-manual_742451204.webp)
8 CIP Message Communications
8-8
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
This section provides examples of route paths.
Output from the Controller in an Industrial PC to a Node on the EtherNet/IP
Network
Communicating between Built-in EtherNet/IP Ports
Example: Communicating between Built-in EtherNet/IP Ports on Controller 1 and Controller 2
•
Network type number: “#02” (Output the command via EtherNet/IP port.)
•
Remote address:
Specify the remote IP address.
•
Route path:
02\192.168.250.2
Communicating from a Built-in EtherNet/IP Port to an EtherNet/IP Unit
Example: Communicating from the built-in EtherNet/IP port on Controller 1 to Controller 2 via the
EtherNet/IP Unit mounted to Controller 2
(1) Controller 1 to EtherNet/IP Unit 2
•
Network type number: “#02” (Output the command via EtherNet/IP port.)
•
Remote address:
Specify the remote IP address.
(2) EtherNet/IP Unit 2 to Controller 2
•
Network type number: “#01” (Output the command via internal backplane port.)
•
Remote address:
“#00” (unit address of Controller)
Route Path Notation Examples
Built-in EtherNet/IP
port
IP address:
192.168.250.2
Controller 2
Built-in EtherNet/IP port
Communications
port (#02)
Controller 1
Backplane
port #01
EtherNet/IP port
IP address:
192.168.250.2
EtherNet/IP Unit 2
Unit address
00 hex
Controller 2
Built-in EtherNet/IP port
Communications
port (#02)
Controller 1
02\192.168.250.2\01\#00
Route path
(1)
(2)
:
Summary of Contents for Sysmac NY512-1300