7-31
7 Tag Data Link Functions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
7-
2 S
e
tti
ng
T
ag
Da
ta
Li
n
ks
7
7-2
-4 Cr
eating T
a
gs an
d T
ag
S
e
ts
The variables will be imported as shown below on the Tag Sets Tab Page. Each variable will be
imported into a different tag set and the device parameters will be automatically edited. (The
variable name will be used for the tag set name.)
To place more than one input variable (input tag) imported from the Sysmac Studio into one tag
set, you must delete the input tags that were registered. Select the tag set containing the vari-
ables you want to put into a tag set, then click the
Delete
Button. A confirmation dialog box is
displayed to confirm that you want to delete the selected tag set and the tags contained in that
tag set. You only want to delete the tag set, so click the
No
Button.
Click the
New
Button to create a new tag set. To place more than one tag in an existing tag set,
double-click the tag set, or select it and click the
Edit
Button. The Edit Tag Set Dialog Box is dis-
played. Imported tags that are not registered in another tag set are displayed in the Candidate
Tag List on the right. Click the Button to add tags individually.