5 Sysmac Studio Settings for the Built-in EtherNet/IP Port
5-10
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
5-5
SNMP Trap Settings Display
SNMP Trap
*1 If you specify to use the SNMP trap, you also have to set the trap 1 and 2 as describe below.
*2 The following ports are used by the system and cannot be set by the user: 25, 53, 68, 110, 2222, 2223, 2224,
9600, and 44818.
Additional Information
Refer to
for details on the SNMP trap.
Setting
Description
Default
SNMP trap
Specify whether to use the SNMP trap (network error detec-
tion).
*1
If the SNMP trap service is not used, SNMP traps are not sent
to the SNMP manager.
Do not use.
Port No.
*2
Set the port number to use to connect to the SNMP server. It is
normally not necessary to change this setting.
162