![Omron Sysmac NY512-1300 User Manual Download Page 48](http://html.mh-extra.com/html/omron/sysmac-ny512-1300/sysmac-ny512-1300_user-manual_742451048.webp)
1 Introduction
1-22
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
Using the CIP Message Communications Service
•
CIP Communications Instructions
Using the Socket Services
Using the FTP Server
Precautions for Correct Use
Precautions for Correct Use
To use the FTP server, you need to make the Virtual SD Memory Card settings in advance.
Refer to the
NY-series Industrial Panel PC / Industrial Box PC Software User’s Manual
(Cat. No.
W558) for information on making the Virtual SD Memory Card settings.
↓
6
Check operation.
1-3-2 Part Names and Func-
tions
Section 14 Checking Com-
munications Status of Net-
work and Troubleshooting
•
Check the built-in EtherNet/IP port indicators.
•
Use the Sysmac Studio to check the communications status with the All Tag
Data Link Communications Status system-defined variable.
•
Use the monitor function of the Network Configurator to confirm that the tag
data links are in normal operation.
1
Execute CIP communications instructions in the user program.
Section 8 CIP Message
Communications
↓
2
Check operation.
1-3-2 Part Names and Func-
tions
Section 14 Checking Com-
munications Status of Net-
work and Troubleshooting
•
Use the Sysmac Studio to check the communications status with the end codes
of the instruction (
Done
,
Error
, and
ErrorID
).
1
Execute the socket service instructions in the user program.
Section 9 Socket Service
↓
2
Check operation.
•
Use the Sysmac Studio to check the communications status with the end codes
of the instruction (
Done
,
Error
, and
ErrorID
).
1
Use the Sysmac Studio to set the initial settings of the EtherNet/IP
Function Module.
Section 10 FTP Server
•
Set the FTP settings (enabling FTP, login name, and password).
↓
2
Connect to the FTP server in NY-series Controller from an FTP cli-
ent application.
•
Input the FTP login name and password to log onto the built-in EtherNet/IP port.
•
Check the event log to see if the FTP server started.