7-43
7 Tag Data Link Functions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
7-
2 S
e
tti
ng
T
ag
Da
ta
Li
n
ks
7
7-2
-6 Cr
eating Connections Using the
Wizard
3
Create the connection following the instructions that are given by the Wizard after the Wizard
starts. (See the following figure.)
4
A list of tag sets is displayed on the right side of the Wizard Dialog Box with target devices that
support receiving input data.
Select the tag sets that you want to receive at the originator device.
The following tables describes the meanings of the icons and check marks displayed in the tag
set list.
Note
Tag sets that are used in connections that are already set are not displayed.
The following display will appear when you click the
Show Detail
Button.
The specified values for detailed parameters will be displayed. Change the values as required. The
connection name cannot be set. They are automatically created using the following rule.
default_N (where N is a 3-digit number (001, 002, etc.) starting from 1)
Icon
Display position
Status
All
All output tag sets for all devices are selected.
Device
All output tag sets for the applicable device are selected.
Tag set
The applicable output tag sets are selected. These are the tag
sets that will be set in the connection.
All
All or some output tag sets for some devices are selected.
Device
Some output tag sets for applicable devices are selected.
All
All output tag sets for all devices are not selected.
Device
All output tag sets for applicable devices are not selected.
Tag set
The applicable output tag sets are not selected. The connec-
tions for this tag set will be deleted.
Device
No applicable tag sets.