The route path indicates the path from the local Controller to the remote Controller on the network.
Routing is performed for CIP communications instructions based on route paths.
The EPATH data type is used to give route paths. The basic format is shown below.
Network_type_number
\
Remote_address
The network type number and the destination address for the Controller in an NY-series Industrial PC
are determined as shown in the following table.
(1) When Routing the Output from the Controller in an Industrial PC to a Node on the
EtherNet/IP Network
Output the command to the built-in EtherNet/IP port. Specify the IP address as the address
of the remote node.
(2) When Routing the Output from the Controller to Windows in an Industrial PC
Output the command to the internal port. Specify the IP address as the address of the
remote node.
Additional Information
Unit Addresses
A unit address is used to discriminate between several devices connected to a single node on a
network.
Set the unit address as shown below.
• Controller: 00 hex
8-2-4
Route Path
Route Path Notation
Network type
Route path notation
Network type number
(hexadecimal)
Destination address
(hexadecimal)
Backplane port
#01
Remote Unit address (Refer to
Additional Information
below.)
Built-in EtherNet/IP port
#02
IP address
Internal Port
#03
NY-series Industrial PC
Controller
Windows
Communications
port (#03)
Backplane port
(#01)
IP address
IP address
(b)
(a)
Communications
port (#02)
Built-in EtherNet/IP port
Internal port
EtherNet/IP
port
(Unit address #00)
(IP address)
(IP address)