Appendices
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
A-2 U
se th
e Sysmac
S
tudio
to
Set t
h
e T
ag Da
ta
L
inks (
E
th
er
N
et/IP Co
nn
ectio
ns)
A
A-2-4 Making
the EtherN
et/IP Connecti
on Settings w
ith th
e Sysmac S
tudio
5
Drag the target device tag set
Net_Out1
in the
Variable Name
column of the Toolbox to the con-
nection list.
As you enter characters (or immediately after you press the Ctrl + Space Keys), a list of target
device variables that can be set for the connection is provided. Select the value from the list.
6
Specify
Originator Variable
and its
Size [Byte]
for the tag set
Net_Out1
added in step 5.
Here, specify
Net_In1
for
Originator Variable
and
2
for its
Size [Byte]
.
Change the other settings as required.
You can set the following items in the connection settings.
Name
Setting Methods
Target Device
Select the target device.
Connection Name
Any name can be given to the connection (32 single-byte characters
max.).
Connection I/O Type
Input Only (Tag type) is selected if EtherNet/IP connections are used
with a CS1W-EIP21, CJ1W-EIP21, CJ2B-EIP21, CJ2M-EIP21, CJ1W-
EIP21(CJ2), CJ1W-EIP21(NJ), NX701, NJ501-
, NJ301-
, NJ101, or NY5
2.
When you create EtherNet/IP connections for other target devices,
select the connection I/O type specified in that device's EDS file.
Use the
Input Only (ID type)
setting when another company's node is
the originator and does not support connection settings with a Tag type
setting.
Input/Output
The connection's input/output is automatically displayed based on the
selected connection.
Input Only: Just
Input
is displayed.
Target Variable
Select the target node's tag set to assign it.
• Input
is specified for
Input/Output
: Select the target's output (pro-
duce) tag set.
• Output
is specified for
Input/Output
: Select the target's input (con-
sume) tag set.
Drag