NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
7-
2 S
e
tti
ng
T
ag
Da
ta
Li
n
ks
7
7-2
-8 Con
necting the
Networ
k C
onfigu
rator
to the Netw
ork
Use the following procedure to directly connect to the built-in EtherNet/IP port via Ethernet. You can
connect to the built-in EtherNet/IP port even if the IP address has not been set on the computer.
1
Select the communications interface.
Select
Option - Select Interface - NJ/NX/NY Series Ethernet Direct I/F
.
2
Select
Network - Connect
and click the
OK
Button.
The Setup Interface Dialog Box is displayed if there are several Controllers that you can con-
nect to.
3
Select the Interface Card to connect and click the
OK
Button.
Select from the options displayed as
Controller model (IP number)
. The following dialog box is
displayed.
4
Select
TCP:2
and then click the
OK
Button.
The following dialog box is displayed.
Direct Connection via Ethernet to Built-in EtherNet/IP Port