13 Communications Performance and Communications Load
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
13-
2 Adju
stin
g t
h
e C
o
mm
un
icatio
ns L
o
ad
13
13-
2-5 R
P
I Setting
E
xamples
In this case, if there is no multicast filter, the value becomes 100.33%. If there is no multicast filter for
an Ethernet switch, communications errors may occur depending on the communications load of the
built-in EtherNet/ IP Unit port.
Method 3: Changing the Packet Intervals (RPIs) of Only Specific Connections
In this example, we want a faster tag data links for just a particular connection of device
192.168.250.1. Double-click device 192.168.250.1 in the Network Configuration Window.
Information about the connection with device 192.168.250.10 is registered in the Register Device
List. Double-click this connection to edit the settings.