The Fault Action setting is not required for input (consume) tag sets.
•
Retain output for major fault:
Hold
(default)
Output data maintains its previous status even after a major fault occurs.
•
Clear output at major fault:
Clear
Output data is cleared to 0 when a major fault occurs.
Precautions for Correct Use
Precautions for Correct Use
Connections are cut off if any of the following errors occurs in the CPU Unit that is the originator
while tag data links are active.
•
Major fault level Controller error
•
Partial fault level Controller error
9
After you register all of the required tags, click the
OK
Button in the Edit Tags Dialog Box.
Select the
Hold
or
Clear
Option.