14-9
14 Checking Communications Status of Network and Troubleshooting
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
14-
2 Connection S
tatus Codes and T
roubleshootin
g
14
14-2 Connection Status Codes and
Troubleshooting
This section explains how to identify and correct errors based on the tag data link’s connection status.
The connection status can be read using the Connection Tab Page of the Network Configurator’s Mon-
itor Device Window. Refer to
14-1 Device Monitoring on the Network Configurator
for details.
Additional Information
The connection status has the same meaning as the Connection Manager’s General and Addi-
tional error response codes, as defined in the CIP specifications.
The following table shows the likely causes of the errors causes for each configuration and connection
status (code).
Originator
Target
Configuration 1
CS1W-EIP21, CJ1W-EIP21, CJ2H-CPU
-
EIP, CJ2M-CPU3
, NJ501-
, NJ301-
, NJ101-
, and NX701-
, NY5
2-
CS1W-EIP21, CJ1W-EIP21, CJ2H-
CPU
-EIP, CJ2M-CPU3
, NJ501-
, NJ301-
, NJ101-
,
and NX701-
, NY5
2-
Configuration 2
CS1W-EIP21, CJ1W-EIP21, CJ2H-CPU
-
EIP, CJ2M-CPU3
, NJ501-
, NJ301-
, NJ101-
, and NX701-
, NY5
2-
Products from other manufacturers
Configuration 3
Products from other manufacturers
CS1W-EIP21, CJ1W-EIP21, CJ2H-
CPU
-EIP, CJ2M-CPU3
, NJ501-
, NJ301-
, NJ101-
,
and NX701-
, NY5
2-
Connection status
Source of error
Handling
General
Status
(hex)
Additional
Status
(hex)
Configuration 1
Configuration 2
Configuration 3
00
0000
Normal status code:
The connection has been opened
and the tag data link is communicat-
ing normally.
---
---
---
01
0100
Error code returned from target:
Attempted to open multiple connec-
tions for the same connection.
This error does not
occur.
Depends on the tar-
get’s specifications.
(This error should not
occur. If is does, con-
tact the target device’s
manufacturer.)
Depends on the origi-
nator’s specifications.
(This error should not
occur. If is does, con-
tact the originator
device’s manufacturer.)
01
0103
Error code returned from target:
Attempted to open a connection with
an unsupported transport class.
This error does not
occur.
Confirm that the target
supports Class 1.
Confirm that the origi-
nator supports Class 1.
01
0106
Duplicate consumers:
Attempted to open multiple connec-
tions for single-consumer data.
If the tag data link is
stopped or started,
this error may occur
according to the tim-
ing, but the system
will recover automat-
ically.
Depends on the tar-
get’s specifications.
(Contact the target
device’s manufacturer.)
If the tag data link is
stopped or started, this
error may occur
according to the tim-
ing, but the system will
recover automatically.
01
0107
Error code returned from target:
Attempted to close a connection, but
that connection was already closed.
This error does not
occur.
This error does not
occur.
This is not an error
because the connec-
tion is already closed.