3Z4L Laser Micrometer Protocol
Appendix N
High Calibration Set (Sequence No. 446 (Hex 01BE))
This sequence sets the Laser Micrometer’s high calibration.
Send Data Word Allocation (3rd Operand of PMCR(260))
Allocations are the same as for sequence No. 404 (Calibration Set) except that the LC gauge dimension in
words +4 to +5 are not used.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note
1.
Use sequences No. 446 (High calibration set) and No. 447 (Low calibration set) to calibrate the Laser
Micrometer. If sequence No. 404 (Calibration Set) is used, both the high and low calibration gauges
must be set, and the high calibration and low calibration gauges cannot be exchanged.
2.
The HC gauge dimension must be set with 3 digits for the integer portion and 4 digits for the decimal
portion.
Low Calibration Set (Sequence No. 447 (Hex 01BF))
This sequence sets the Laser Micrometer’s low calibration.
Send Data Word Allocation (3rd Operand of PMCR(260))
Allocations are the same as for sequence No. 404 (Calibration Set) except that the HC gauge dimension in
words +1 to +3 are not used.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note
1.
Use sequences No. 446 (High calibration set) and No. 447 (Low calibration set) to calibrate the Laser
Micrometer. If sequence No. 404 (Calibration Set) is used, both the high and low calibration gauges
must be set, and the high calibration and low calibration gauges cannot be exchanged.
2.
The LC gauge dimension must be set with 3 digits for the integer portion and 4 digits for the decimal
portion.
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...