![Omron SYSMAC CJ1W-SCU21-V1 Operation Manual Download Page 649](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586649.webp)
620
K3T
@
Intelligent Signal Processor Protocol
Appendix L
Receive Data Word Allocation (4th Operand of PMCR(260))
The work allocation is similar to sequence No. 337 (Model Data Read (by Unit Number)).
General-purpose Command (Sequence No. 339 (Hex 0153))
Sends the specified data and writes the receive data to the receive data words. The characters such as “@”,
FCS, terminators need not be set in the send and receive data words. These characters will be automatically
added for transmission and automatically removed before saving data.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (3rd Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 to 00FA (3 to 250 decimal)
+1
Send data byte length (4 digits BCD)
0001 to 01F0 (1 to 496 decimal)
Number of bytes of send data not including
@, the FCS, and the terminator.
+2 to
+249
Send data (ASCII)
ASCII
Send data: 496 characters max.
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits Hex)
0001 to 00FA (1 to 250 decimal)
+1 to
+249
Receive data (ASCII)
ASCII
Receive data: 498 characters max.
Send data byte length
+0
+1
+2
+3
+249
Number of send data words
First word of
send data
~
~
Send data
Send data
Send data
+0
+1
+2
+3
+249
Number of receive data words
Receive data
storage words
~
~
Receive data
Receive data
Receive data
Receive data
Summary of Contents for SYSMAC CJ1W-SCU21-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 89: ...60 Basic Operating Procedure Section 1 9...
Page 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Page 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Page 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Page 277: ...248 Communications Frames Section 6 8...
Page 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Page 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Page 391: ...362 Introduction Appendix A...
Page 421: ...392 CompoWay F Master Protocol Appendix B...
Page 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Page 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Page 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Page 627: ...598 ES100 Digital Controller Protocol Appendix K...
Page 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Page 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Page 717: ...688 Visual Inspection System Protocol Appendix O...
Page 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Page 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Page 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Page 781: ...752 Revision History...